6E2–138
RODEO 6VD1 3.2L ENGINE DRIVEABILITY AND EMISSIONS
3. If DTC P0112 can be repeated only by duplicating
the Failure Records condition, refer to the
Temperature vs. Resistance Value table. The table
may be used to test the IAT sensor at various
temperatures to evaluate the possibility of a
"shifted" sensor that may be stored above or below
a certain temperature. If this is the case, replace
the IAT sensor. If the IAT sensor appears to be OK,
the fault is intermittent; refer to Diagnostic Aids .
Intake Air Temperature Sensor
°C
Temperature
vs. Resistance
Values
(approximate)
100
80
60
45
35
25
15
5
–5
–15
–30
–40
°F
OHMS
212
177
176
332
140
667
113
1188
95
1802
77
2796
59
4450
41
7280
23
12300
5
21450
–22
52700
–40
100700