EPSON AcuLaser C1100
4.13.19 HARNESS-ASSY FEED 2
REMOVAL
1.
Remove 500 PAPER FEEDER ASSY.
2.
Remove COVER LEFT 500.
(p.453)
3.
Unclamp the clamp fastening the harness of HARNESS-ASSY FEED 2.
4.
Disconnect connector (P/J436) from PWBA-TRAY 500.
5.
Unhook the 2 hooks fastening HARNESS-ASSY FEED 2 to 500 PAPER
FEEDER ASSY, and remove HARNESS-ASSY FEED 2.
REINSTALLATION
1.
Attach HARNESS-ASSY FEED 2 to 500 PAPER FEEDER ASSY, and fasten
with the hook.
2.
Connect connector (P/J436) to PWBA-TRAY 500.
3.
Fasten the harness of HARNESS-ASSY FEED 2 with the clamp.
4.
Attach COVER LEFT 500.
(p.453)
5.
Attach 500 PAPER FEEDER ASSY.
DISASSEMBLY AND ASSEMBLY
(p.452)
(p.452)
500 PAPER CASSETTE & 500 PAPER FEEDER
3)
5)-2
3)
4)
5)-1
Figure 4-165. Removal of HARNESS-ASSY FEED 2