EPSON AcuLaser C1100

4.5.12 CAM ASSY-IBT CL

REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove COVER ASSY LH.
(p.295)
3.
Remove OP PANEL.
(p.294)
4.
Remove COVER INNER TOP.
5.
Remove PWBA MCU.
(p.404)
When performing the following work, there is no need to remove
C A U T I O N
SENSOR IBT RETRACT from BRACKET-SENSOR CLN.
6.
Remove SENSOR IBT RETRACT.
7.
Remove the left and right E-rings fastening CAM ASSY-IBT CL to the main unit.
8.
Remove the left and right BEARING-BRUSH CAMs fastening CAM ASSY-IBT
CL to the main unit.
9.
Temporarily slide CAM ASSY-IBT CL to the left, and draw out the shaft of CAM
ASSY-IBT CL from the right-side bearing on the main unit to remove CAM
ASSY-IBT CL.
REINSTALLATION
1.
Insert the shaft left side of CAM ASSY-IBT CL into the left-side bearing of the
main unit, slide CAM ASSY-IBT CL to the right, and attach CAM ASSY-IBT CL.
2.
Fasten CAM ASSY-IBT CL to the main unit by the left and right BEARING-
BRUSH CAMs.
3.
Fasten CAM ASSY-IBT CL to the main unit by the left and right E-rings.
DISASSEMBLY AND ASSEMBLY
(p.299)
(p.357)
4.
Attach SENSOR IBT RETRACT.
The shutter of CAM ASSY-IBT CL must be inserted inside the
C A U T I O N
sensor on SENSOR IBT RETRACT.
5.
Attach PWBA MCU.
6.
Attach COVER INNER TOP.
7.
Attach OP PANEL.
(p.294)
8.
Attach COVER ASSY LH.
9.
Attach COVER ASSY RH.
7)
8)
Figure 4-71. Removal of CAM ASSY-IBT CL
TRANSFER
(p.357)
(p.404)
(p.299)
(p.295)
(p.301)
Revision B
9)
7)
8)
Leg_Sec03_075EB
360