4.4.7 ROLL REGI RUBBER

REMOVAL
1.
Remove FRAME ASSY-PH.
(p.327)
2.
Remove MOTOR-PH.
(p.337)
3.
Remove DRIVE ASSY-PH.
(p.340)
4.
Remove CLUTCH ASSY REGI.
5.
Remove the E-ring fastening GEAR-REGI on ROLL REGI RUBBER from
FRAME ASSY-PH, and remove GEAR-REGI.
6.
Remove the right-side BEARING RUBBER and SPRING-REGI R (METAL)
fastening ROLL REGI RUBBER from FRAME ASSY-PH.
7.
Remove the E-ring fastening ROLL REGI RUBBER from FRAME ASSY-PH,
and BEARING RUBBER and SPRING-REGI L (BLACK) on the left side.
8.
Temporarily slide ROLL REGI RUBBER to the left, draw out the shaft on ROLL
REGI RUBBER from the right-side bearing on FRAME ASSY-PH, and remove
ROLL REGI RUBBER.
DISASSEMBLY AND ASSEMBLY
(p.329)
D cut surface
(METAL)
6)-2
6)-1
5)-2
5)-1
RIGHT
Figure 4-48. Removal of ROLL REGI RUBBER
PH ASSY
Revision B
8)
(BLACK)
7)-2
7)-1
Leg_Sec03_060FB