Actuator Empty - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

4.3.12 ACTUATOR EMPTY

Step numbers with [ ] in the figure indicate the step of
C A U T I O N
reinstallation.
REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove COVER ASSY LH.
(p.295)
3.
Remove COVER MSI.
(p.291)
4.
Remove COVER FRONT L and COVER FRONT ASSY U.
5.
Remove FRAME ASSY-PH.
(p.327)
6.
Remove MSI ASSY.
(p.304)
7.
Remove GUIDE SIDE L and GUIDE ASSY SIDE R.
When performing the following work, connectors need not be
C H E C K
P O I N T
disconnected from SENSOR PAPER EMPTY.
8.
Remove SENSOR PAPER EMPTY.
9.
Remove the holes on PLATE BOTTOM 2 from the boss on PLATE BOTTOM
ASSY MSI while extending the attachment sections on the left and right of
PLATE BOTTOM 2.
10. Turn PLATE BOTTOM 2, remove the bosses on the left and right of PLATE
BOTTOM 2 from the notches of MSI ASSY, and remove PLATE BOTTOM 2.
When performing the following work, take care not to fold
C A U T I O N
ACTUATOR EMPTY.
DISASSEMBLY AND ASSEMBLY
(p.292)
(p.310)
(p.321)
11. Remove the groove on the left-side shaft on ACTUATOR EMPTY from the hook
on MSI ASSY, and draw out the right-side shaft on ACTUATOR EMPTY from
the hole on MSI ASSY.
12. Slide ACTUATOR EMPTY to the left, slide the shaft of ACTUATOR EMPTY
along the notch of MSI ASSY, and remove ACTUATOR EMPTY.
9)
Figure 4-38. Removal of ACTUATOR EMPTY (1)
MSI
10)
9)
Leg_Sec03_052FB
Revision B
322

Hide quick links:

Advertisement

Table of Contents
loading