1.6 Conditions for Storage and Transport

1.6.1 Ambient Temperature and Humidity

Condition
Temperature (°C)
Normal
0 to 35
conditions
High
35 to 40
Harsh
conditions
Low
-20 to 0
Note *1: Non-condensing

1.6.2 Storage Altitude

0 to 3, 100 m or less
For air transport, 0 to 15, 000 m. However, this assumes that the cargo compartment is
maintained at 70.9275 kPa or higher.

1.6.3 Dropping

There should be no damage on 1 corner, 3 edges, and 6 sides of the packages under the
conditions below.
Standard
Main unit
500-sheet cassette unit
Option
Duplex unit
PRODUCT DESCRIPTION
Table 1-22.
1
Humidity*
(%RH)
Guarantee period
12 months after
15 to 80
manufacture
High
80 to 95
Max. 48 hours
Low
5 to 15
Table 1-23.
Drop
610mm
760mm
910mm
Conditions for Storage and Transport

1.6.4 Vibration

There should be no damage under the following conditions
Frequency
: 5 to 55 Hz
Acceleration
: 1.5 G
However, between 5 to 10 Hz, constant 7.5 mm
double amplitude is assumed.
Frequency sweep
: Logarithmic sweep 10 minutes for one-way
Direction of application
: X, Y, Z directions
Number of cycles
: 3 cycles for each of XYZ directions (each 1 hour)