4.4.4 FRAME ASSY-PH

Step numbers with [ ] in the figure indicate the step of
C A U T I O N
reinstallation.
REMOVAL
1.
In the case of the DUPLEX specification, remove DUPLEX ASSY.
2.
In the case of the standard specification, remove COVER-PH.
3.
Open CHUTE ASSY-REAR.
4.
Remove the 4 screws (silver, with flange, 8 mm) fastening FRAME ASSY-PH to
the main unit.
5.
Close CHUTE ASSY-REAR.
When performing the following work, take care not to remove
C A U T I O N
FRAME ASSY-PH too far as it is connected by a harness.
6.
Slightly remove FRAME ASSY-PH together with CHUTE ASSY-REAR from the
main unit.
7.
Disconnect connector (P/J603) and connector (P/J604) connected to the main unit,
and remove FRAME ASSY-PH together with CHUTE ASSY-REAR.
8.
Remove CHUTE ASSY-REAR.
DISASSEMBLY AND ASSEMBLY
(p.412)
(p.324)
(p.325)
4)
4)
6)
8)
Figure 4-43. Removal of FRAME ASSY-PH
PH ASSY
3)
4)
4)
7)
Leg_Sec03_057EA
Revision B
327