Sensor Ibt Retract - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

4.5.10 SENSOR IBT RETRACT

REMOVAL
1.
Remove OP PANEL.
(p.294)
2.
Remove COVER INNER TOP.
3.
Disconnect connector (P/J107) from SENSOR IBT RETRACT.
4.
Remove the screw (silver, with flange, 6 mm) fastening BRACKET-SENSOR
CLN to the main unit.
5.
Remove BRACKET-SENSOR CLN from the main unit together with SENSOR
IBT RETRACT.
6.
Unhook the three hooks fastening SENSOR IBT RETRACT to BRACKET-
SENSOR CLN, and remove SENSOR IBT RETRACT.
REINSTALLATION
1.
Match the hooks on SENSOR IBT RETRACT with the attachment position, and
attach to BRACKET-SENSOR CLN.
2.
Match the hole on BRACKET-SENSOR CLN with the boss on the main unit, and
attach BRACKET-SENSOR CLN together with SENSOR IBT RETRACT.
The shutter of CAM ASSY-IBT CL must be inserted inside the
C A U T I O N
sensor on SENSOR IBT RETRACT.
3.
Fasten BRACKET-SENSOR CLN to the main unit with the screw (silver, with
flange, 6 mm).
4.
Connect connector (P/J107) to SENSOR IBT RETRACT.
5.
Attach COVER INNER TOP.
(p.299)
6.
Attach OP PANEL.
(p.294)
DISASSEMBLY AND ASSEMBLY
(p.299)
6)-1
Figure 4-69. Removal of SENSOR IBT RETRACT
TRANSFER
4)
5)
6)-2
3)
CAUTION
Leg_Sec03_074FA
Revision B
357

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents