REINSTALLATION
1.
Match the protrusion and boss on GUIDE CRU ASSY AD with the hole on the
main unit, and attach GUIDE CRU ASSY AD.
2.
Fasten GUIDE CRU ASSY AD to the main unit with the 7 screws (silver, with
flange, tapping, 6 mm).
3.
Attach PLATE-ASSY GND to the main unit, and tighten together with GUIDE
CRU ASSY AD with the screw (silver, with flange, tapping, 6 mm).
When performing the following work, work can be performed more
C H E C K
P O I N T
easily with LEVER-LATCH PR on GUIDE CRU ASSY AD closed.
4.
Attach SPRING-LATCH onto the main unit and the stud on GUIDE CRU ASSY
AD.
5.
Attach WIRE ASSY DTN to GUIDE CRU ASSY AD.
6.
Fasten WIRE ASSY DTN to GUIDE CRU ASSY AD with the screw (silver, with
flange, tapping, 6 mm).
7.
Attach WIRE ASSY BTR, WIRE ASSY IBT and WIRE ASSY BCR to GUIDE
CRU ASSY AD.
8.
Attach PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD.
9.
Fasten PLATE-TR-0 to GUIDE CRU ASSY D and GUIDE CRU ASSY AD with
the 2 screws (silver, with flange, tapping, 6 mm).
10. Attach SENSOR TR-0.
(p.361)
11. Attach BCR CLN XERO ASSY.
12. Attach FRAME ASSY-PH.
(p.327)
13. Attach 2ND BTR ASSY.
(p.348)
14. Attach COVER ASSY RH.
(p.301)
DISASSEMBLY AND ASSEMBLY
(p.373)
Table 4-3. Symptoms when the connector is loose
Connector
Panel Indication
No.
D (504)
---
A (508)
---
G (506)
---
XERO
Error Caused by Connector
Symptom
Disconnection
Printed light
---
and faint.
Entire surface
---
printed black.
Normal printing
---