EPSON AcuLaser C1100
4.6.6 LEVER-LATCH PR
REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove 2ND BTR ASSY.
(p.348)
3.
Remove FRAME ASSY-PH.
(p.327)
4.
Remove BCR CLN XERO ASSY.
5.
Remove SENSOR TR-0.
(p.361)
6.
Remove GUIDE CRU ASSY AD.
7.
Turn LEVER-LATCH PR in the direction of the arrow, match the notch on
LEVER-LATCH PR with the protrusion on the boss of GUIDE CRU ASSY AD,
and remove LEVER-LATCH PR.
REINSTALLATION
1.
Match the notch on LEVER-LATCH PR with the protrusion on the boss of
GUIDE CRU ASSY AD, and attach LEVER-LATCH PR.
2.
Attach GUIDE CRU ASSY AD.
3.
Attach SENSOR TR-0.
(p.361)
4.
Attach BCR CLN XERO ASSY.
5.
Attach FRAME ASSY-PH.
(p.327)
6.
Attach 2ND BTR ASSY.
(p.348)
7.
Attach COVER ASSY RH.
(p.301)
DISASSEMBLY AND ASSEMBLY
(p.373)
(p.367)
(p.367)
(p.373)
Figure 4-81. Removal of LEVER-LATCH PR