EPSON AcuLaser C1100
4.4.3 CHUTE-REAR UP, CHUTE-REAR LOW
Step numbers with [ ] in the figure indicate the step of
C A U T I O N
reinstallation.
REMOVAL
1.
Remove CHUTE ASSY-REAR.
2.
Remove the 2 screws (silver, with flange, tapping, 8 mm) fastening CHUTE-
REAR LOW to CHUTE-REAR UP.
3.
Remove the concave portion on CHUTE-REAR LOW from the protrusion on
CHUTE-REAR UP, and remove CHUTE-REAR LOW from CHUTE-REAR UP.
REINSTALLATION
1.
Match the hole on CHUTE-REAR LOW with the boss on CHUTE-REAR UP, and
insert the protrusion on CHUTE-REAR UP into the concave portion on CHUTE-
REAR LOW to attach.
The protrusion on CHUTE REAR UP must be inserted firmly into
C A U T I O N
the concave portion on CHUTE-REAR LOW.
2.
Fasten CHUTE-REAR LOW to CHUTE-REAR UP with the 2 screws (silver, with
flange, tapping, 8 mm).
3.
Attach CHUTE ASSY-REAR.
(p.325)
DISASSEMBLY AND ASSEMBLY
(p.325)
2)
[1)]
CAUTION
Figure 4-42. Removal of CHUTE-REAR UP and CHUTE-REAR LOW
PH ASSY
3)-2
2)
3)-1
Leg_Sec03_056FA
Revision B
326