EPSON AcuLaser C1100
REINSTALLATION
1.
Match the boss on ROS ASSY with the hole on the main unit, and attach ROS
ASSY.
When performing the following work, press LATCH ROTARY on
C A U T I O N
LATCH ASSY-ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent
contact with MAG ROLL.
2.
Fasten ROS ASSY to the main unit with the 5 screws (silver, with flange, 10mm).
3.
Attach the ground lead of ROS ASSY to the main unit, and fasten with the screw
(silver, with flange, 6 mm).
4.
Connect connector (P/J601) and connector (P/J602) to ROS ASSY.
5.
Attach CLEANER ASSY.
(p.377)
6.
Attach FRAME ASSY-PH.
(p.327)
7.
Attach COVER INNER L.
(p.302)
8.
Attach COVER FRONT L and COVER FRONT ASSY U.
9.
Attach COVER MSI.
(p.291)
10. Attach COVER ASSY LH.
(p.295)
11. Attach COVER ASSY RH.
(p.301)
DISASSEMBLY AND ASSEMBLY
(p.292)
ROS
Revision B
376