EPSON AcuLaser C1100

4.8 DEVE

4.8.1 LATCH ASSY-ROTARY

REMOVAL
1.
Remove COVER ASSY LH.
(p.295)
2.
Remove LV/HVPS.
(p.407)
3.
Remove the 3 screws (silver, with flange, tapping, 8 mm) fastening LATCH
ASSY-ROTARY to the main unit.
4.
Unhook the three hooks fastening LATCH ASSY-ROTARY to the main unit, and
remove LATCH ASSY-ROTARY.
REINSTALLATION
Pay attention to the levers and springs inside LATCH ASSY-
C A U T I O N
ROTARY as they easily come loose.
When a part on LATCH ASSY-ROTARY comes off, referring to
the assembly drawing, assemble the part, and attach LATCH
ASSY-ROTARY to the main unit.
1.
Match the hook on LATCH ASSY-ROTARY with the attachment position, and
attach to the main unit.
2.
Fasten LATCH ASSY-ROTARY to the main unit with the 3 screws (silver, with
flange, tapping, 8 mm).
3.
Attach LV/HVPS.
(p.407)
4.
Attach COVER ASSY LH.
(p.295)
DISASSEMBLY AND ASSEMBLY
4)-1
3)
3)
3)
4)-2
Figure 4-88. Removal of LATCH ASSY-ROTARY
DEVE
Revision B
CAUTION
Leg_Sec03_088EB