EPSON AcuLaser C1100
FIP-41
Panel Message
Service Req E514
Possible parts that caused the error
FFC-ASSY ESS
PWBA ESS
Troubleshooting
Step
Check
Check of connection of FFC-ASSY ESS
1
Re-connect FFC-ASSY ESS of PWBA ESS to
PWBA MCU. Does the error recur when a test
print is made?
Check of connection of FFC-ASSY ESS
2
Is FFC-ASSY ESS damaged or broken?
Check after replacement of PWBA MCU
3
Replace PWBA MCU.
(p.404)
Does the error recur when a test print is made?
TROUBLESHOOTING
PWBA MCU
Yes
No
Go to Step [2].
End of
procedure
Replace FFC-
Go to Step [3].
ASSY ESS.
(p.409)
Replace PWBA
End of
ESS.
(p.409)
procedure
FIP according to the printer message
FIP-42
Panel Message
Service Req E513
Possible parts that caused the error
PWBA MCU
Troubleshooting
Step
Check
Does the error recur when the power is
1
turned off and back on?
Does the error recur even when the
2
power is turned off and back on again?
Does the error recur even after the power
3
has been switched several times?
Disconnect and re-connect all connectors
4
connected to PWBA MCU.
Does the error recur when the power is
turned ON?
Check after replacement of PWBA MCU
5
Replace PWBA MCU.
(p.404)
Does the error recur when the power is
turned ON?
*1: It is assumed to be due to external noise.
Proceed to
"FIP-79 Electrical Noise"
Revision B
Yes
No
Go to Step [4].
Go to Step [2].
Go to Step [4].
Go to Step [3].
Go to Step[4].
End of
procedure*
Go to Step [5].
End of
procedure
Go to
"FIP-79
End of
Electrical
procedure
Noise".
(p.238)