EPSON AcuLaser C1100
2.
Match the hole on HOUSING ASSY-DEVE with the attachment hole on the left
side of FRAME ASSY-ROTARY, insert the shaft on PIVOT ASSY, and fasten
the left side of HOUSING ASSY-DEVE with the screw (silver, with flange,
tapping, 8 mm).
3.
Match the hole on HOUSING ASSY-DEVE with the attachment hole on the right
side of FRAME ASSY-ROTARY, insert the shaft of PIVOT AD, and fasten the
hook on PIVOT AD to attach HOUSING ASSY-DEVE.
Removed PIVOT ADs should not be re-used; only new PIVOT ADs
C A U T I O N
in the KIT should be used.
4.
Attach GUIDE CRU ASSY AD.
5.
Attach SENSOR TR-0.
(p.361)
6.
Attach BCR CLN XERO ASSY.
7.
Attach FRAME ASSY-PH.
(p.327)
8.
Attach 2ND BTR ASSY.
(p.348)
9.
Attach COVER ASSY TOP.
(p.283)
10. Attach COVER ASSY RH.
(p.301)
11. Attach the Toner Cartridge.
12. Use CLEANER ASSY to clean the window of ROS ASSY.
When replaced HOUSING ASSY-DEVE with a new one, clear the
C A U T I O N
DEVE life counter to zero. (Refer to
Items"
(p497))
DISASSEMBLY AND ASSEMBLY
(p.367)
(p.373)
"6.3.1 Maintenance Menu
DEVE
Revision B