EPSON AcuLaser C1100

4.4.8 ROLL ASSY-PRE REGI

REMOVAL
1.
Remove FRAME ASSY-PH.
(p.327)
2.
Remove MOTOR-PH.
(p.337)
3.
Remove DRIVE ASSY-PH.
(p.340)
4.
Remove CLUTCH ASSY PRE REGI.
5.
Remove the E-rings fastening the right side of the shaft on ROLL ASSY-PRE
REGI from FRAME ASSY-PH.
6.
Remove the left and right BEARING METALs fastening ROLL ASSY-PRE
REGI from FRAME ASSY-PH.
7.
Open CHUTE ASSY-REAR.
8.
Temporarily slide ROLL ASSY-PRE REGI to the left, draw out the shaft on
ROLL ASSY-PRE REGI from the right-side bearing on FRAME ASSY-PH, and
remove ROLL ASSY-PRE REGI.
REINSTALLATION
Attach ROLL ASSY-PRE REGI to FRAME ASSY-PH so that the
C A U T I O N
D cut surface of the shaft comes to the left side.
1.
Insert the shaft left side on ROLL ASSY-PRE REGI into the left-side bearing on
FRAME ASSY-PH, and slide ROLL ASSY-PRE REGI to the right to attach.
2.
Close CHUTE ASSY-REAR.
3.
Match the double D cut surface of BEARING METAL with the left and right
bearings of FRAME ASSY-PH, attach BEARING METAL, and fasten ROLL
ASSY-PRE REGI.
4.
Fasten the shaft right side of ROLL ASSY-PRE REGI with an E-ring.
DISASSEMBLY AND ASSEMBLY
(p.338)
5.
Attach CLUTCH ASSY PRE REGI.
6.
Attach DRIVE ASSY-PH.
7.
Attach MOTOR-PH.
(p.337)
8.
Attach FRAME ASSY-PH.
D cut surface
6)
Figure 4-49. Removal of ROLL ASSY-PRE REGI
PH ASSY
(p.338)
(p.340)
(p.327)
7)
8)
Leg_Sec03_061FB