EPSON AcuLaser C1100
4.12 DUPLEX
4.12.1 DUPLEX ASSY
REMOVAL
When performing the following, take care not to damage DUPLEX
C A U T I O N
ASSY by falling or dropping it.
1.
Press LINK-BUTTON upward to release the latch and open DUPLEX ASSY.
2.
Remove COVER CONNECTOR, and disconnect connector (P/J607) connected to
the main unit.
3.
Remove the 2 SCREW SUPPORTs fastening the left and right SUPPORT DUPs
to the main unit.
4.
Remove the 2 SCREW THUMBs fastening DUPLEX ASSY to the main unit.
5.
Slightly lift up DUPLEX ASSY, unhook the both left and right hooks on
DUPLEX ASSY from the holes on the main unit, and remove DUPLEX ASSY.
REINSTALLATION
1.
Hook the left and right hooks on DUPLEX ASSY onto the holes on the main unit,
and attach DUPLEX ASSY.
2.
Fasten DUPLEX ASSY to the main unit with the 2 SCREW THUMBs.
3.
Fasten the left and right SUPPORT DUPs to the main unit with the 2 SCREW
SUPPORTs.
4.
Connect connector (P/J607) connected to the main unit and attach COVER
CONNECTOR.
5.
Gently close DUPLEX ASSY.
DISASSEMBLY AND ASSEMBLY
5)-1
2)-2
Figure 4-115. Removal of DUPLEX ASSY
DUPLEX
Revision B
3)
3)
5)-2
2)-1
4)
4)
Leg_Sec03_115EA
412