Pwb Assy Rot - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

4.11.3 PWB ASSY ROT

Avoid staticky places such as on a carpet especially when removing
C A U T I O N
or inserting a Board. Before starting work with the Board, make
sure to touch metallic portion of the printer connected to the earth
to let your body come out free of static electricity.
REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove COVER ASSY LH.
(p.295)
3.
Remove COVER MSI.
(p.291)
4.
Remove COVER FRONT L and COVER FRONT ASSY U.
5.
Disconnect connector (P/J430), connector (P/J432) and connector (P/J433) from
PWB ASSY ROT.
6.
Remove the 4 screws (silver, with flange, 6 mm) fastening PWB ASSY ROT to
the main unit.
7.
Remove PWB ASSY ROT from the main unit.
REINSTALLATION
1.
Attach PWB ASSY ROT to the main unit.
2.
Fasten PWB ASSY ROT to the main unit with the 4 screws (silver, with flange, 6
mm).
3.
Connect connector (P/J430), connector (P/J432) and connector (P/J433) to PWB
ASSY ROT.
4.
Attach COVER FRONT L and COVER FRONT ASSY U.
5.
Attach COVER MSI.
(p.291)
6.
Attach COVER ASSY LH.
(p.295)
7.
Attach COVER ASSY RH.
(p.301)
DISASSEMBLY AND ASSEMBLY
(p.292)
6)
6)
(p.292)
ELEC
7)
6)
5)
6)
Figure 4-108. Removal of PWB ASSY ROT
Revision B