Maintenance Menu; Maintenance Menu Items - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

6.3 Maintenance Menu

This menu is provided only for a service personnel to perform
C A U T I O N
maintenance.
Do not disclose it to the users.
This menu is displayed and selectable only when a special operation performed at
power-on to enter the maintenance mode. Basically, this menu is provided to be used
by a service personnel for maintenance.
At the time of maintenance, print the Engine Status Sheet from the Maintenance Menu
and grasp the usage conditions of various consumables and components needing
periodic replacement.

6.3.1 Maintenance Menu Items

This menu is displayed and selectable only when a special operation performed at
power-on to enter the maintenance mode.
When the power is then turned off once and on again, the Maintenance Menu is deleted
(the printer returns to the normal operating mode).
*1
Engine Status Sheet
Before entering the maintenance mode, make sure that there is no engine-related
service call in the normal operating mode (not maintenance mode).
After the printer enters into the maintenance mode, press the Enter switch to print
an engine status sheet. The sheet is printed according to the default settings, except
RIT, toner save, and resolution settings (current settings are applied for those
settings). While the printing is in progress, the LCD keeps flashing. The user
default environment (settings) does not change after the printing.
The contents of the engine status sheet are the counted values of each unit which
makes up the printer engine.
*2
Print Log Report
Prints a log file of printing status.
Reset 2ndBTRCounter
Reset the counter of the 2nd BTR assy consumption and count up the exchange
counter. The counter must be reset after the 2nd BTR assy is replaced with a new
one. After executing the counter reset, open and close the cover A. Do not turn the
printer off until the engine stops completely.
MAINTENANCE
Reset Y (M, C, K) DvlpCounter
Reset the counter of the Y (M, C, K) developer unit consumption and count up the
exchange counter. The counter must be reset after the Y (M, C, K) developer unit
is replaced with a new one. After executing the counter reset, open and close the
cover A. Do not turn the printer off until the engine stops completely.
Reset Fuser Counter
Reset the counter of the fuser assy consumption and count up the exchange
counter. The counter must be reset after the Fuser unit is replaced with a new one.
When resetting the counter, the number of printed pages for the Fuser Assy is
stored on the EEPROM. The stored value will be printed on the Engine Status
Sheet as the number of previous replacement.
Same function is also available in the reset menu. (See
C H E C K
P O I N T
Menu"
Clear Error Log
Clear error log list stored for display on Engine Status Sheet.
Performing this operation reboots the printer.
MCU DATA BackUp
Backup the data of the engine. "MCU Data BackUp" is displayed until back up
processing ends.
MCU DATA Restore
Restore the data of the engine to the mechanical controller. "MCU DATA
Restore" is displayed until restore processing ends.
NOTE *1: Refer to
*2: Refer to
*3: Execution of the mechanical controller backup is not possible in the
following states:
• During a power save
• During warming-up
• During printing
• During printer adjustments
The power must not be turned OFF during the backup/restore process
until the engine has stopped.
Maintenance Menu
(p50))
*3
*3
"6.4.1 Engine Status Sheet" (p499)
"6.4.2 Print Log Report" (p504)
Revision B
" Reset
497

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents