Epson AcuLaser C1100 Service Manual page 166

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100
Step
Check
Operation check of SENSOR REGI
11
The voltage of P408-12 ↔ P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensor sensing area, and is 5
VDC when it leaves the sensing area?
5 VDC power supply check to SENSOR REGI
12
The voltage of P408-10 ↔ P408-11 on
PWBA MCU is 5 VDC?
Continuity check of HARNESS-ASSY P/H1
13
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-10 ↔ J603-3
J408-11 ↔ J603-2
J408-12 ↔ J603-1
Continuity check of HARNESS-ASSY P/H2
14
Disconnect P/J603 and P/J102 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
P603-10 ↔ J102-3
P603-11 ↔ J102-2
P603-12 ↔ J102-1
5 VDC power supply check to PWBA MCU
15
The voltage of P410-3 ↔ P410-4 on PWBA
MCU is 5 VDC?
Continuity check of HARNESS ASSY MAIN
16
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-3 ↔ J502-3
J410-4 ↔ J502-4
TROUBLESHOOTING
Yes
No
Go to Step [17].
Go to Step [12].
Go to Step [13].
Go to Step [15].
Go to Step [14].
Replace
HARNESS-
ASSY P/H1.
Replace
Replace
SENSOR
HARNESS-
REGI.
(p.336)
ASSY P/H2.
Replace PWBA
Go to Step [16].
MCU.
(p.404)
Replace LV/
Repair broken
HVPS.
(p.407)
or shorted part.
FIP according to the printer message
Step
Check
24 VDC power supply check to P/H MOTOR
17
The voltage of P409-6 ↔ P409-5 on PWBA
MCU is 24 VDC?
Continuity check of HARNESS-ASSY P/H1
18
Disconnect the P/J409 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J409-1 ↔ P604-6
J409-2 ↔ P604-5
J409-3 ↔ P604-4
J409-4 ↔ P604-3
J409-5 ↔ P604-2
J409-6 ↔ P604-1
Check after replacement of MOTOR-PH
19
Replace MOTOR-PH.
(p.337)
Does the error recur when a test print is made?
24 VDC power supply check to PWBA MCU
20
The voltage of P410-5/6 ↔ P410-7/8 on
PWBA MCU is 24 VDC?
Continuity check of HARNESS ASSY MAIN
21
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-5 ↔ J502-5
J410-6 ↔ J502-6
J410-7 ↔ J502-7
J410-8 ↔ J502-8
Continuity check of HARNESS-ASSY P/H1
22
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-1 ↔ J603-12
J408-2 ↔ J603-11
Revision B
Yes
No
Go to Step [18].
Go to Step [20].
Go to Step [19].
Replace
HARNESS-
ASSY P/H1.
Replace PWBA
End of
MCU.
(p.404)
procedure
Replace PWBA
Go to Step [21].
MCU.
(p.404)
Replace LV/
Repair broken
HVPS.
(p.407)
or shorted part.
Go to Step [23].
Replace
HARNESS-
ASSY P/H1.
166