Sensor Upper Pass - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

4.12.9 SENSOR UPPER PASS

REMOVAL
1.
Remove DUPLEX ASSY.
(p.412)
2.
Remove COVER-R DUP.
(p.413)
3.
Remove COVER-L DUP.
(p.414)
4.
Remove LINK-LATCH and LINK-BUTTON.
5.
Open COVER UP-DUP TRANS, and remove INVERTER ASSY DUP. Note that
COVER LOW-DUP TRANS and COVER UP-DUP TRANS need not be
removed.
(p.417)
6.
Remove COVER-INV.
(p.415)
7.
Remove the screw (silver, with flange, tapping, 10 mm) fastening BRACKET-
SNS to INVERTER ASSY DUP.
8.
Remove BRACKET-SNS from INVERTER ASSY DUP together with SENSOR
UPPER PASS.
9.
Disconnect connector (P/J124) from SENSOR UPPER PASS.
10. Unhook the 3 hooks fastening SENSOR UPPER PASS to BRACKET-SNS, and
remove SENSOR UPPER PASS.
DISASSEMBLY AND ASSEMBLY
(p.416)
DUPLEX
10)-2
10)-1
Figure 4-124. Removal of SENSOR UPPER PASS
Revision B