Epson AcuLaser C1100 Service Manual page 185

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100
Step
Check
Check of ROLLER ASSY DUP, ROLLER
9
ASSY DUP OUT and ROLL PINCH DUP
Open Duplex.
Are ROLLER ASSY DUP, ROLLER ASSY
DUP OUT, and ROLL PINCH DUP attached
correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
Does the error recur when a test print is
10
made in the duplex mode?
Check of transmission of drive force to
11
ROLLER ASSY DUP
Open Duplex.
Remove COVER-L DUP.
(p.414)
Are all gears that transmit rotation of MOTOR
ASSY DUP (Lower Roll Motor) to ROLLER
ASSY DUP turning smoothly?
Turn gears by hand to check.
Check after replacement of MOTOR ASSY
12
DUP (Lower Roll Motor)
Replace MOTOR ASSY DUP.
Does the error recur when a test print is made
in the duplex mode?
Check after replacement of PWBA DUP-L
13
Replace PWBA DUP-L.
(p.442)
Does the error recur when a test print is made
in the duplex mode?
Shape and operation check of ROLL
14
ASSY-PRE REGI and ROLL-PINCH
Open CHUTE ASSY-REAR.
Are ROLL ASSY-PRE REGI and ROLL-
PINCH attached correctly?
Also, do these parts rotate smoothly without
any dirt or damage?
Turn by hand to check.
TROUBLESHOOTING
Yes
Go to Step [11].
Replace or re-
attach ROLL in
question, and go
to [10].
Go to Step [11].
End of
procedure
Go to Step [12].
Replace the
gear in question.
Go to Step [13].
End of
procedure
(p.443)
Go to Step [14].
End of
procedure
Go to Step [15].
Replace ROLL
in question.
FIP according to the printer message
No
Step
Does the error recur when a test print is
15
made?
Check of paper position
16
Is the leading edge of the paper passing
through PRE REGI ROLL?
Operation check of ACTUATOR-REGI
17
Does ACTUATOR-REGI move smoothly
without any damage? Does it enter the sensor
sensing area when there is paper? Does it
leave the sensor sensing area when there is no
paper?
Operation check of SENSOR REGI
18
The voltage of P408-12 ↔ P408-11 on
PWBA MCU is 0 VDC when ACTUATOR
REGI enters the sensor sensing area, and is 5
VDC when it leaves the sensing area?
5 VDC power supply check to SENSOR REGI
19
The voltage of P408-10 ↔ P408-11 on
PWBA MCU is 5 VDC?
Continuity check of HARNESS-ASSY P/H1
20
Disconnect the P/J408 from PWBA MCU.
Do all of the wiring below have normal
continuity?
J408-10 ↔ J603-3
J408-11 ↔ J603-2
J408-12 ↔ J603-1
Continuity check of HARNESS-ASSY P/H2
21
Disconnect P/J603 and P/J102 from PWBA
MCU.
Do all of the wiring below have normal
continuity?
P603-10 ↔ J102-3
P603-11 ↔ J102-2
P603-12 ↔ J102-1
Check
Yes
Go to Step [16].
Go to Step [17].
Go to Step [18].
Go to Step [24].
Go to Step [20].
Go to Step [21].
Replace
SENSOR
REGI.
(p.336)
Revision B
No
End of
procedure
Go to Step [29].
Replace
ACTUATOR-
REGI.
(p.335)
Go to Step [19].
Go to Step [22].
Replace
HARNESS-
ASSY P/H1.
Replace
HARNESS-
ASSY P/H2.
185

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents