History (Rmon Group 2); Alarm (Rmon Group 3) - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series configuration guide v02.7.02
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

TABLE 161
This line...
512 to 1023 octets pkts
1024 to 1518 octets pkts
NOTE
The number of entries in a RMON statistics table directly corresponds to the number of ports on a
system. For example, if the system is a 26 port device, there will be 26 entries in the statistics
display.

History (RMON group 2)

All active ports by default will generate two history control data entries per active BigIron RX
interface. An active port is defined as one with a link up. If the link goes down the two entries are
automatically be deleted.
Two history entries are generated for each device:
The history data can be accessed and displayed using any of the popular RMON applications
A sample RMON history command and its syntax is shown below.
BigIron RX(config)# rmon history 1 interface 1 buckets 10 interval 10 owner nyc02
Syntax: rrmon history <entry-number> interface ethernet <slot/port> | management <num>
You can modify the sampling interval and the bucket (number of entries saved before overwrite)
using the CLI. In the above example, owner refers to the RMON station that will request the
information.
NOTE
To review the control data entry for each port or interface, enter the show rmon history command.

Alarm (RMON group 3)

Alarm is designed to monitor configured thresholds for any SNMP integer, time tick, gauge or
counter MIB object. Using the CLI, you can define what MIB objects are monitored, the type of
thresholds that are monitored (falling, rising or both), the value of those thresholds, and the
sample type (absolute or delta).
An alarm event is reported each time that a threshold is exceeded. The alarm entry also indicates
the action (event) to be taken if the threshold be exceeded.
BigIron RX Series Configuration Guide
53-1001810-01
Export configuration and statistics (Continued)
a sampling of statistics every 30 seconds
a sampling of statistics every 30 minutes
buckets <number> interval <sampling-interval> owner <text-string>
Displays...
The total number of packets received that were 512 – 1023 octets long.
This number includes bad packets.
This number does not include framing bits but does include FCS octets.
NOTE: Not supported in BigIron RX.
The total number of packets received that were 1024 – 1518 octets
long.
This number includes bad packets.
This number does not include framing bits but does include FCS octets.
NOTE: Not supported in BigIron RX.
38
RMON support
1023