Patton electronics SmartNode Series Software Configuration Manual page 407

Software for smartnode series
Hide thumbs Also See for SmartNode Series:
Table of Contents

Advertisement

SmartWare Software Configuration Guide
Class
Protocol
ie-does-not-exist
Error
(Cont.)
invalid-ie-contents
recovery-on-timer-
expiry
protocol-error
interworking
Inter-
working
Example: Create a hunt group service
This example shows how to configure the hunt group service as shown in
SN(cfg)#context cs
SN(ctx-cs)[switch]#service hunt-group HUNT-BRI
SN(func)[HUNT-BRI]#cyclic
SN(func)[HUNT-BRI]#timeout 6
SN(func)[HUNT-BRI]#route dest-interface IF-BRI0
SN(func)[HUNT-BRI]#route dest-interface IF-BRI1
SN(func)[HUNT-BRI]#route dest-interface IF-BRI2
SN(func)[HUNT-BRI]#route dest-interface IF-BRI3
Call router configuration task list
Table 20. Hunt group drop causes (Continued)
Default Behavior
Cause
of the Hunt
Group Service
Drop original call
Drop original call
Drop original call
Drop original call
Drop original call
33 • Call router configuration
Description
The remote equipment receives a message
that includes information elements or call
properties that are not recognized.
The remote equipment receives a message
that includes invalid information in the
information element or call property.
Your call was not completed, probably
because an error occurred.
An unspecified protocol error with no
other standard cause occurred.
An event occurs, but the network does not
provide causes for the action it takes. The
precise problem is unknown.
figure 66
on page 397.
405