Patton electronics SmartNode Series Software Configuration Manual page 151

Software for smartnode series
Hide thumbs Also See for SmartNode Series:
Table of Contents

Advertisement

SmartWare Software Configuration Guide
MAC Address
: 00:30:2B:00:1D:D4
Speed
: 10Mbps
Duplex
: Half
Encapsulation
: ip
Binding
: wan@router
Frame Format
: standard
Default Service: 0
Moreover the IP interface, which is bound to the Ethernet port on slot 0 and port 0 gets also closed. Checking
the state of the IP interface wan indicates this with the CLOSED for parameter state.
SN(prt-eth)[0/1]#show ip interface
------------------------------------------------------------
Context:
Name:
IP Address:
MTU:
ICMP router-discovery:
ICMP redirect:
State:
Binding:
Ethernet port configuration task list
router
wan
172.17.100.210 255.255.255.0
1500
enabled
send only
CLOSED
ethernet 0 0 1/ethernet/ip
13 • Ethernet port configuration
149

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartNode Series and is the answer not in the manual?

Subscribe to Our Youtube Channel

This manual is also suitable for:

Smartware release 3.10

Table of Contents