SmartWare Software Configuration Guide
default address completion timeout is 12 seconds and is restarted after each digit that is sent during overlap
dialing.
Note
The address completion timeout is active when the call router waits for man-
datory digits before being able to complete call routing. Contrary to this, the
digit collection timeout, described below, waits for additional optional dig-
its.
Procedure: To configure the address completion timeout
Mode: Context CS
Step
1
node (ctx-cs)[ switch ]#
address-completion timeout timeout
Example: Configure address completion timeout
SN[switch]#address-completion timeout 20
Configures the address completion timeout to 20s. A call with an incomplete called party number is dropped
20 seconds after receiving the last called party address update (overlap dialed digit).
Configure default digit collection timeout and terminating character
You can enter called party routing table entries that specify an incomplete number (extended by the T-indica-
tor; refer to section
"Called party number routing table"
entry, the call router waits for additional digits and starts the digit collection timeout. When the digit collec-
tion timeout elapses or when the user enters the terminating character, the call is placed to the destination
specified with the routing table entry.
The digit collection timeout has a default value of 5 seconds, the terminating character is the pound character
(#) by default.
Note
The digit completion timeout is active when the call router waits for
optional digits of a called party number before placing the call to the selected
destination. Contrary to this, the address completion timeout, described
above, waits for mandatory digits.
Procedure: To configure the digit collection timeout and terminating character
Call router configuration task list
Command
33 • Call router configuration
Purpose
Configures the address completion timeout by
specifying the timeout in seconds. If not config-
ured, the default address completion timeout is
12 seconds.
on page 372). When the call router selects such an