4.9 Arming/Disarming Options And Exit/Entry Delay

4.9.1 Configuring Exit Modes

Here you determine exit delay mode options. Three types of exit delay modes are available:
restart exit - Exit delay restarts when the door is reopened during exit delay. The restart occurs once only.
Restarting the exit delay is helpful if the user re-enters immediately after going out to retrieve an item that he left
behind.
off by door - When the door is closed, the exit delay is automatically terminated (even if the defined exit delay
was not completed).
normal (default) - The exit delay is exactly as defined, regardless of whether the door is open or closed.
To Configure the Exit Modes
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
09:EXIT MODE
4.
normal
or
5.
6.
09:EXIT MODE

4.9.2 Configuring Entry Delays Duration

Two different entry delays allow the user to enter the protected site (while the system is in the armed state) via 2
specific doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-rate warning beeps
start sounding once the door is opened, until the last 10 seconds of the delay, during which the beeping rate
increases. Locations No. 1 (entry delay 1) and 2 (entry delay 2) allow you to program the length of these delays.
Available options for each delay are: "00s", "15s" (default for entry delay 2), "30s" (default for entry delay 1),
"45s", "60s", "3m" and "4m".
Note: To comply with CP-01 requirements, "
Note: To comply with EN requirements, the entry delay must not exceed 45 sec
Note: To comply with UL requirements, the entry delay must not exceed 45 sec
To Configure the Duration of the Entry Delays
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
62
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "restart exit", "off by door", and "normal".
You can now press the
menu in "
03:CONTROL PANEL
"
".
<OK> TO EXIT
" and "
" options are not available
00s
15s
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
*
or
button to program any other
" or press the
.
.
.
button to take you to
D-303145