Configuring Arming/Disarming And Exit/Entry Procedures - Visonic PowerMaster-10 Installer's Manual

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

– Entering the "Control Panel" Menu
To Select an Option:
[1]
Enter the "Installer Menu" and select the "03.CONTROL PANEL" option (see section 3.2).
Identify the option you wish to configure and then scroll and select that option, for example: "45: STROBE TIME"
[2]
in the "Sirens" group.
Note: A quick shortcut procedure may be used by keying the 2 digit serial No. of the Option indicated in
the option screen as shown in the chart, for example "46" for "46:SIREN ON LINE", which brings you
directly to that option
[3]
To continue, refer to the section indicated in Step 2 for the Group Section of the selected option, for
example section 3.5.5 for the "Sirens" group, and look for the option you wish to configure (for example,
"46:SIREN ON LINE"). After configuring the selected parameter the display returns to step 2.
To Change the Configuration of the Selected Option:
When entering the selected option, the display shows the default (or the previously selected) setting marked
with ( ).
If you wish to change the configuration, scroll
desire and press

3.5.2 Configuring Arming/Disarming and Exit/Entry Procedures

The following table provides you with a detailed description of each option and its configuration settings. To
select an option and change its configuration – refer to section 3.5.1.
Option
01:ENTRY DELAY1
02:ENTRY DELAY2
Notes: To comply with UL requirements, the entry delay must not exceed 15 sec.
03:EXIT DELAY
Notes: To comply with UL requirements, the exit delay must not exceed 120 sec.
04:EXIT MODE
D-303222 PowerMaster-10 / PowerMaster-30 Installer's Guide
to confirm. When done the display brings you back to Step 2.
Configuration Instructions
Two different entry delays allow the user to enter the protected site (while the system is
in the armed state) via dedicated exit/entry doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires.
Slow-rate warning beeps start sounding once the door is opened, until the last 10
seconds of the delay, during which the beeping rate increases. The "Entry Delay 1" and
"Entry Delay 2" options allow you to program the time length of these delays.
Option settings: 00 seconds; 15 seconds (default for entry delay 2); 30 seconds
(default for entry delay 1); 45 seconds; 60 seconds; 3 minutes and 4 minutes.
To comply with CP-01 requirements, "00s" and "15s" delays must not be used.
To comply with EN requirements, the entry delay must not exceed 45 sec.
An exit delay allows the user to arm the system and leave the protected site via specific
routes and exit/entry doors without causing an alarm. Slow-rate warning beeps start
sounding once the arming command has been given, until the last 10 seconds of the
delay, during which the beeping rate increases. The "Exit Delay" option allows
programming of time length of the exit delay.
Option settings: 30 seconds; 60 seconds (default); 90 seconds; 120 seconds,
3 minutes and 4 minutes.
To comply with CP-01 requirements, the "30s" delay must not be used.
The "Exit Delay" time can be further adjusted according to your preferred exit route.
PowerMaster-10 provides you with the following "Exit Mode" options:
the "Option settings" menu and select the setting you
45