Visonic PowerMaster-10 Installer's Manual page 84

Fully supervised wireless alarm control system
Hide thumbs Also See for PowerMaster-10:
Table of Contents

Advertisement

Fault
What it means
MISSING
A device or detector has not reported for
some time to the control panel.
JAMMING
A radio-frequency signal which is blocking
communication channel of sensors and
control panel is detected.
LOW BATTERY
The battery in a sensor, keyfob or wireless
commander is near the end of its useful life.
CLEAN ME
The fire detector must be cleaned
GAS TROUBLE
Gas detector failure
SIREN AC
There is no power to the siren
FAILURE
AC FAILURE
There is no power to gas sensor
GSM NET FAIL
The GSM communicator is not able to
connect to the cellular network.
RSSI LOW
The GSM communicator has detected that
GSM network signal is weak
AC SUPPLY
There is no power and the system is working
FAILURE
on backup battery power
COMM. FAILURE
A message could not be sent to the
monitoring station or to a private telephone
(or a message was sent but was not
acknowledged)
CPU LOW
The backup battery within the control panel
BATTERY
is weak and must be replaced (see
Chapter 7 - Replacing Backup Battery).
CPU TAMPER
The control panel was physically tampered
with or its cover was opened, or it was
removed from wall.
D-303145
Solution
i) Make sure the device is physically
present.
ii) Check the display for device faults, for
example, low battery.
iii) Use RF diagnostics to check the current
signal strength and during the last 24
hours.
iv) Replace the battery.
v) Replace the device.
Locate the source of interference by
switching
off
any
(cordless telephones, wireless ear plugs,
etc.) in the house for 2 minutes then check
if trouble continues.
Use also RF diagnostics to check signal
strength.
i) For AC powered devices, check AC
power is available and connected to the
device.
ii) Replace the device battery.
Use a vacuum cleaner to clean the
detector air vents occasionally to keep
them free of dust.
Gas detector: Disconnect and then put
back the AC power supply connector
CO Gas detector: Replace the detector
Make sure that the AC power supply is
connected properly
Make sure that the AC power supply is
connected properly
i) Move the Panel and GSM unit to
another location.
ii) Enter and exit the installer menu
iii) Disconnect GSM unit and install it again
iv) Replace SIM card
v) Replace the GSM unit
Move the Panel and GSM unit to another
location.
Make sure that the AC power supply is
connected properly
i)
Check telephone cable connection
ii) Check that correct telephone number
has been dialed.
iii) Dial
Monitoring
whether or not events are received.
i) Check for AC power is available in the
Panel.
ii) If trouble exists for more than 72 hours,
replace the battery pack
The control panel is not closed properly.
Open the control panel and then close it.
wireless
devices
Station
to
check
83