Configuring Arming/Disarming And Exit/Entry Procedures - Visonic PowerMaster-10 G2 Quick User Manual

Version 17
Hide thumbs Also See for PowerMaster-10 G2:
Table of Contents

Advertisement

To enter the "03.CONTROL PANEL" menu and to select and configure an option, proceed as follows:
Step 1
Select "CONTROL PANEL"
option
INSTALLER MODE
03.CONTROL PANEL

5.5.2 Configuring Arming/Disarming and Exit/Entry Procedures

The following table provides you with a detailed description of each option and its configuration settings. To select an
option and change its configuration – refer to section 5.5.1.
Option
01:ENTRY DELAY1
02:ENTRY DELAY2
1
Soak Test is not applicable for UL installations.
D-304762 PowerMaster-10/30 G2 Installer's Guide
Step 2
Select the "Control Panel" Parameter you wish to configure
See
Arming &
5.5.2
Disarming
01:ENTRY DELAY1
02:ENTRY DELAY2
03:EXIT DELAY
04:EXIT MODE
05:QUICK ARM
06:BYPASS ARM
07:LATCHKEY ARM
08:DISARM OPTION
09:ARMING KEY
Zone
5.5.3
Behavior
21:SWINGER STOP
22:CROSS ZONING
Configuration Instructions
Two different entry delays allow the user to enter the protected site (while the system is in the
armed state) via dedicated exit/entry doors and routes without causing an alarm.
Following entry, the user must disarm the control panel before the entry delay expires. Slow-
rate warning beeps start sounding once the door is opened, until the last 10 seconds of the
delay, during which the beeping rate increases. The "ENTRY DELAY 1" and
"ENTRY DELAY 2" options allow you to program the time length of these delays.
Options: 00 seconds; 15 seconds (default for entry delay 2); 30 seconds (default for entry
delay 1); 45 seconds; 60 seconds; 3 minutes and 4 minutes.
Notes:
1. In some PowerMaster variants, these menus are displayed in the Operation
Mode only (see section 5.15).
2. To comply with UL requirements, the entry delay must not exceed 15 sec unless a
keypad is used. If a keypad is used, the entry delay shall not exceed 45 seconds.
3. To comply with CP-01 requirements, "00s" and "15s" delays must not be used.
See
Alarms &
5.5.4
Troubles
31:PANIC ALARM
32:DURESS ALARM
33:INACTIVE ALRT
34:TAMPER ALARM
35:AC FAIL REPRT
36:CONFIRM ALARM
37:ABORT TIME
38:CANCEL ALARM
39:ALARM RESET
40:ABORT FIRE T.
Sirens
5.5.5
43:PANEL SIREN
44:SIREN TIME
45:STROBE TIME
46:SIREN ON LINE
5. PROGRAMMING
See
User
5.5.6
Interface
51:PIEZO BEEPS
52:TROUBLE BEEPS
53:MEMORY PROMPT
54:LOW-BAT ACK
55:BACK LIGHT
56:SCREEN SAVER
Jamming and
5.5.7
Supervision
61:JAM DETECT
62:MISSING REPRT
63:NOT READY
64:MISS/JAM ALRM
65:SMOK FAST MIS
Miscellaneous
5.5.8
91:USER PERMIT
92:BATTERY TYPE
1
93:SOAK PERIOD
Step 3
Configure
option
Go to the
indicated
group
section of
the
selected
option
When
done
to
Step 2
37

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powermaster-30 g2

Table of Contents