2.
COMMUNICATING
TEL# NOT DEFINED
DOWNLOADING
DIAL ATTEMPT FAIL
DOWNLOAD OK
DOWNLOAD FAILED

7. MAINTENANCE

7.1 Handling System Troubles

Fault
What it means
1-WAY
The control panel cannot configure or
control the device.
Battery consumption increases.
NOT
A device was not installed or not installed
NETWORKED
correctly,
communication with the control panel after
installation.
82
If the UL/DL server telephone number was already defined (see section
4.7.3.1 "Configuring the Types of Events to be Reported"), the
PowerMaster-10 display will read "COMMUNICATING" which is displayed
during the dialing process.
If the UL/DL server telephone number was not defined (see section
4.7.3.1 "Configuring the Types of Events to be Reported"), the
PowerMaster-10 display will read "TEL# NOT DEFINED" which is
displayed for approx. 30 sec. and is followed by a sad (failure) tune.
If communication has been established between the PowerMaster-10
control panel and the upload/download server, the PowerMaster-10
display will read "DOWNLOADING" which is displayed during the dialing
process.
If communication has failed between the PowerMaster-10 control panel
and the upload/download server, the PowerMaster-10 display will read
"DIAL ATTEMPT FAIL" which is displayed for approx. 30 sec. and is
followed by a sad (failure) tune.
After
the
downloaded/uploaded
successfully, the PowerMaster-10 display will read "DOWNLOAD OK"
which is displayed for approx. 30 sec. and is followed by a happy
(success) tune.
If communication has been established between the PowerMaster-10
control
panel
and
downloaded/uploaded process has failed, the PowerMaster-10 display
will read "DOWNLOAD FAILED" which is displayed for approx. 30 sec. and
is followed by a sad (failure) tune.
Clicking the
takes you one level up with each click. Clicking the
take you to "
<OK> TO EXIT
or,
cannot
establish
process
the
upload/download
button repeatedly at any stage in the procedure
".
Solution
i) Make sure the device is physically
present.
ii) Check the display for device faults, for
example, low battery.
iii) Use RF diagnostics to check the current
signal strength and during the last 24
hours.
iv) Open the device cover and replace the
battery or press the tamper switch.
v) Install the device in a different location.
vi) Replace the device.
i) Make sure the device is physically
present.
ii) Use RF diagnostics to check the current
signal strength and during the last 24
hours.
iii) Open the device cover and replace the
battery or press the tamper switch.
iv) Enroll the device again.
has
been
completed
server
but
the
button will
D-303145