4.8 Security System Configuration

4.8.1 Configuring Cross Zoning

Cross zoning is a method used to counteract false alarms - an alarm will not be initiated unless two adjacent
zones are violated within a 30-second time limit.
This feature is active only when arming AWAY and only with zone couples from zone No. 18 to 27 (18 and 19,
20 and 21, etc.). You may use any one of these zone couples to create a "cross-zoned" area.
Note: If one of two crossed zones is bypassed (see Para. 4.3.5), the remaining zone will function independently.
Note: Every 2 crossed zones must be of the allowed zone type (Interior, Perimeter, Perimeter follower).
The options are: cross zone ON and cross zone OFF (default).
Cross zoning is not applicable in Entry/ Exit zones and 24h zones (Fire, Emergency, 24h audible, 24h silent).
To Enable Cross Zoning
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
14:CROSS ZONING
4.
cross zone OFF
or
5.
6.
14:CROSS ZONING
D-303145
Here you determine whether to enable or disable the motion camera for
taking pictures after an emergency type event.
Select between "Enable" and "Disable".
You can now press the
" menu, or press the
CAMERA
".
EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "cross zone OFF" and "cross zone ON".
You can now press the
menu in "
03:CONTROL PANEL
"
".
<OK> TO EXIT
button to revert to the "
button to take you to "
or
button to program any other
" or press the
5:MOTION
<OK> TO
button to take you to
55