4.8.4 Configuring Alarm Cancel Period

Here you determine the "cancel alarm" period that starts upon reporting an alarm to the Monitoring Station. If the
user disarms the system within that time period, a "cancel alarm" message is sent to the Monitoring Station.
Available options are: cancel time 1 m, cancel time 5 m (default), cancel time 15 m, cancel time 60 m,
cancel time 4 hours and also cancel inactive (default in USA).
Note: To comply with CP-01 requirements, "1 minute" option is not available
To Configure the Alarm Cancel Period
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
06:ALARM CANCEL
4.
cancel time 5 m
or
5.
6.
06:ALARM CANCEL

4.8.5 Configuring Power Failure Threshold Period

Here you determine the time interval between AC power failure occurrence and the failure reporting.
Options: 5 minutes (default), 30 minutes, 60 minutes or 180 minutes.
Note: To comply with EN requirements, set to 60 min. max.
To Configure the Power Failure Threshold Period
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
D-303145
You can now press the
menu in "
03:CONTROL PANEL
"
".
<OK> TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "cancel time 1 m", "cancel time 5 m", "cancel time
15 m", "cancel time 60 m", "cancel time 4 h", and "cancel
inactive".
You can now press the
menu in "
03:CONTROL PANEL
"
".
<OK> TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
or
button to program any other
" or press the
.
or
button to program any other
" or press the
button to take you to
button to take you to