4.8.7 Configuring a Confirmed Alarm

Here you determine that if 2 successive alarms will occur during a specific period, the second alarm will be
considered as a confirmed alarm for confirmed alarm reporting, (see par. 4.6.3.2 "Configuring the Event Types
to be Reported").
Options: disable (default in USA), 30 min., 45 min., 60 min. (default), or 90 min.
To Configure a Confirmed Alarm
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
33:CONFIRM TIME
4.
60 minutes
or
5.
6.
33:CONFIRM TIME

4.8.8 Enable Alarm upon Detection of Jammed or Missing Device

Here you determine whether an alarm will be initiated (siren / report) when there is a supervision / jamming
failure during AWAY arming state.
Available options are: EN standard and other (default). When "EN standard" is selected, if there is
supervision / jamming failure during AWAY arming, the siren is activated and the events are reported as
tamper events. When "Other" is selected, there is no such activity during AWAY arming.
To Enable an Alarm Upon Detection of a Jammed or Missing Device
1.
03:CONTROL PANEL
2.
01:ENTRY DELAY 1
or
3.
30:BELL/REP.OPT
4.
other
or
5.
6.
D-303145
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "disable", "30 minutes", "45 minutes", "60
minutes", and "90 minutes".
You can now press the
menu in "
03:CONTROL PANEL
"
".
<OK> TO EXIT
Repeat steps 1 to 4 of section 4.2 "Entering the Installer Menu".
Select between "EN standard", and "other".
or
button to program any other
" or press the