Item
Description
1
Online spare memory LED
2
Mirrored memory LED
All other LEDs
IMPORTANT:
If more than one FBDIMM slot LED is illuminated, further troubleshooting is required. Test each bank
of FBDIMMs by removing all other FBDIMMs. Isolate the failed FBDIMM by replacing each FBDIMM
in a bank with a known working FBDIMM.
NOTE:
The HP Systems Insight Display LEDs represent the system board layout.

Rear Panel Components

Item
Description
1
Expansion slot 1 blank
2
Expansion slot 2 blank
3
Quad port FC card, host port, port 0
4
Quad port FC card, host port, port 1
Status
Green = Protection enabled
Flashing amber = Memory configuration error
Amber = Memory failure occurred
Off = No protection
Green = Protection enabled
Flashing amber = Memory configuration error
Amber = Memory failure occurred
Off = No protection
Amber = Failure
Off = Normal. For additional information
detailing the causes for the activation of these
LEDs, refer to
HP Systems Insight Display LEDs
and Internal Health LED