Vibration
Shock
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m
(10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage
corresponds to a pressure minimum of 70 KPa.
Operating
Non-operating
5-1000-5 Hz, 0.25
5-1000-5 Hz, 1.0
g, sinusoidal, 1
g, sinusoidal, 1
Octave/min., 3-axis
Octave/min., 3-axis
5 g, every 11ms,
25 g, every 11ms,
1/2 sine pulse, 3
1/2 sine pulse, 3
axis
axis
Shipping
5-1000-5 Hz, 2.0
g, sinusoidal, 1
Octave/min., 3-axis
30 g, every 11ms,
1/2 sine pulse, 3
axis