Locating and Removing the Torx T-15 Tool (VLS6800 node only)

1.
Locate the Torx T-15 tool on the back of the node.
2.
Slide the tool upward out of the retaining clips.
Figure 90 Removing the Torx T-15 tool
.

Extending a VLS6100, VLS6200, or VLS6500 Node from the Rack

WARNING!
To reduce the risk of personal injury or equipment damage, be sure that the rack is adequately
stabilized before extending a node from the rack.
WARNING!
Be careful when pressing the rail-release levers and sliding the component into or out of the rack. The
sliding rails could pinch your fingertips.
To extend a node from the rack:
1.
Loosen the thumbscrews that secure the node faceplate to the front of the rack.
2.
Extend the node on the rack rails until the node rail-release latches engage.
3.
After performing the replacement procedure, slide the node back into the rack:
a.
Press the node rail-release latches and slide the node fully into the rack.
b.
Secure the node by tightening the thumbscrews.

Extending a VLS6600 Node from the Rack