System board LED
and color
DIMM failure, all
slots in one bank
(Amber)
Overtemperature
(Amber)
Riser interlock (Am-
ber)
Online spare
memory (Amber)
Power converter
module interlock
(Amber)
Fan module (Amber)
Fan module (Red)
Power supply signal
interlock (Amber)
Fan Module Locations
Item
Description
1
Power supply zone fan module (fan 1)
2
Processor zone fan module (fan 2)
222
Component Identification
Internal Health
Status
LED Color
•
DIMM in slot X has reached single-bit correctable error
threshold.
•
DIMM in slot X is in a pre-failure condition.
Amber
•
DIMM in slot X is an unsupported type, but valid memory exists
in another bank.
Red
No valid or usable memory is installed in the system.
Amber
The Health Driver has detected a cautionary temperature level.
Red
The node has detected a hardware critical temperature level.
Red
The PCI riser board assembly is not seated.
Amber
Bank X failed over to the online spare memory bank.
Red
The power converter module is not seated.
Amber
A redundant fan has failed.
The minimum fan requirements are not being met in one or more
Red
of the fan modules. One or more fans have failed or are missing.
The power supply signal cable is not connected to the system
Red
board.
Need help?
Do you have a question about the StorageWorks 6000 - Virtual Library System and is the answer not in the manual?