Fan Module Locations - HP StorageWorks 6000 - Virtual Library System User Manual

Hp storageworks 6000-series virtual library system user guide (ah809-96038, march 2010)
Hide thumbs Also See for StorageWorks 6000 - Virtual Library System:
Table of Contents

Advertisement

System board LED
and color
DIMM failure, all
slots in one bank
(Amber)
Overtemperature
(Amber)
Riser interlock (Am-
ber)
Online spare
memory (Amber)
Power converter
module interlock
(Amber)
Fan module (Amber)
Fan module (Red)
Power supply signal
interlock (Amber)

Fan Module Locations

Item
Description
1
Power supply zone fan module (fan 1)
2
Processor zone fan module (fan 2)
222
Component Identification
Internal Health
Status
LED Color
DIMM in slot X has reached single-bit correctable error
threshold.
DIMM in slot X is in a pre-failure condition.
Amber
DIMM in slot X is an unsupported type, but valid memory exists
in another bank.
Red
No valid or usable memory is installed in the system.
Amber
The Health Driver has detected a cautionary temperature level.
Red
The node has detected a hardware critical temperature level.
Red
The PCI riser board assembly is not seated.
Amber
Bank X failed over to the online spare memory bank.
Red
The power converter module is not seated.
Amber
A redundant fan has failed.
The minimum fan requirements are not being met in one or more
Red
of the fan modules. One or more fans have failed or are missing.
The power supply signal cable is not connected to the system
Red
board.