Map 600 Event Codes - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
Table 10: MAP 600 Event Codes
Event
Code
080
081
506
507
512
514
581
582
583
584
585
586
4
Is fault isolation being performed at the switch?
YES
5
Each port has an amber LED and a blue (2 Gb/s operation) or green (1 Gb/s
operation) LED adjacent to the port. The amber LED illuminates and the blue or
green LED extinguishes if the port fails.
Is an amber port LED illuminated but not blinking (beaconing)?
YES
94
Explanation
Unauthorized worldwide name.
Invalid attachment.
Fibre Channel port failure.
Loopback diagnostics port failure.
SFP optical transceiver nonfatal error.
SFP optical transceiver failure.
Implicit incident.
Bit error threshold exceeded.
Loss of signal or loss of synchronization.
Not operational primitive sequence received.
Primitive sequence timeout.
Invalid primitive sequence received for current link
state.
NO
Fault isolation is being performed at the EWS interface or HAFM
appliance. Go to
step
NO
The switch appears operational, however a link incident or other
problem may have occurred. Perform fault isolation at the HAFM
appliance. Go to
step
7.
13.
Edge Switch 2/24 Service Manual
Action
Go to
step
21.
Go to
step
22.
Go to
step
6.
Go to
step
18.
Go to
step
6.
Go to
step
6.
Go to
step
34.
Go to
step
34.
Go to
step
34.
Go to
step
34.
Go to
step
34.
Go to
step
34.