Diagnostics
Table 4: Event Codes versus Maintenance Action (Continued)
Event
Code
510
512
513
514
523
524
525
581
582
583
584
585
586
810
811
30
Explanation
SFP optical transceiver hot-insertion
initiated.
SFP optical transceiver nonfatal error.
SFP optical transceiver hot-removal
completed.
SFP optical transceiver failure.
FL_Port open request failed.
No AL_PA acquired.
FL_Port arbitration timeout.
Implicit incident.
Bit error threshold exceeded.
Loss of signal or loss of synchronization.
Not operational primitive sequence
received.
Primitive sequence timeout.
Invalid primitive sequence received for
current link state.
High temperature warning (CTP thermal
sensor).
Critically hot temperature warning (CTP
thermal sensor).
Action
No action required.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
No action required.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
No action required.
No action required.
No action required.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0600: Port
Failure and Link Incident
Analysis.
Go to
MAP 0500: FRU
Failure
Analysis.
Go to
MAP 0500: FRU
Failure
Analysis.