MAP 0100: Power Distribution Analysis

This MAP describes fault isolation for the switch power distribution system,
including defective AC power cords or redundant power supplies.
1
Was an event code 200 or 201, 202, 208 observed at the EWS Event Log or at the
Edge Switch Event Log (HAFM appliance)?
YES
2
Table 5
that describe fault isolation procedures.
Table 5: MAP 100 Event Codes
Event
Code
200
201
202
208
3
Have the customer inspect and verify that facility power is within specifications.
These specifications are:
Is facility power within specifications?
YES
Edge Switch 2/24 Service Manual
NO
Go to
step
9.
lists event codes, brief explanations of the codes, and the associated steps
Explanation
Power supply AC voltage failure.
Power supply DC voltage failure.
Power supply thermal failure.
Power supply false shutdown.
One single-phase connection for each power supply.
Input power between 100 and 240 VAC, and at least 5 amps.
Input frequency between 47 and 63 Hz.
NO
Ask the customer to correct the facility power problem. When facility
power is corrected, continue to the next step.
Action
Go to
step
3.
Go to
step
8.
Go to
step
8.
Go to
step
3.
Diagnostics