Figure 56: Redundant power supply removal and replacement
4. Perform one of the following to inspect the Event Log. Note that multiple
Edge Switch 2/24 Service Manual
events appear because the power supply contains three internal cooling fans.
If at a Web browser connected to the EWS interface, click the Log tab at the
Monitor panel. The Event Log displays. The following event codes appear:
— 200–Power supply AC voltage failure (recorded when AC power is
disconnected).
— 300–A cooling fan propeller has failed (first fan).
— 301–A cooling fan propeller has failed (second fan).
— 302–A cooling fan propeller has failed (third fan).
— 206–Power supply removed.
If at the HAFM appliance, open the Hardware View, click Logs > Event
Log. The Event Log displays. The Event Log displays. The following event
codes appear:
— 200–Power supply AC voltage failure (recorded when AC power is
disconnected).
— 300–A cooling fan propeller has failed (first fan).
— 301–A cooling fan propeller has failed (second fan).
— 302–A cooling fan propeller has failed (third fan).
— 206–Power supply removed.
FRU Removal and Replacement
199