Event Codes
Table 56: Event Code 202
Message:
Power supply thermal failure.
Severity:
Major.
Explanation:
The thermal sensor associated with a power supply indicates an overheat condition
that shut down the power supply. The second power supply assumes the full
operating load for the switch.
Action:
Replace the failed power supply. Perform the data collection procedure and return
the backup disk and failed power supply to HP support personnel.
Event Data:
No supplementary data included with this event.
Distribution:
Switch
EWS
Event Log
Table 57: Event Code 203
Message:
Power supply AC voltage recovery.
Severity:
Informational.
Explanation:
AC voltage recovered for the power supply. Both power supplies adjust to share
operating load for the switch.
Action:
No action required.
Event Data:
No supplementary data included with the event.
Distribution:
Switch
EWS
Event
Log
Table 58: Event Code 204
Message:
Power supply DC voltage recovery.
Severity:
Informational.
Explanation:
DC voltage recovered for the power supply. Both power supplies adjust to share
operating load for the switch.
Action:
No action required.
Event Data:
No supplementary data included with the event.
270
HAFM Appliance
System
Event Log
Error LED
HAFM Appliance
System
Event
Error
Log
LED
E-Mail
Call
Home
E-Mail
Call
Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents