Double-click anywhere in a row for an installed port to open the Port Properties
dialog box.
Right-click anywhere in a row for an installed port to open a menu to:
Edge Switch 2/24 Service Manual
#—The switch port number (0 through 139 inclusive).
Name—The port name configured through the Configure Ports dialog box.
Block Config—The port status (Blocked or Unblocked).
State—The operating state of the port. Valid states are:
— Online, Offline, or Testing
— Beaconing
— Invalid Attachment
— Link Incident or Link Reset
— No Light, Not Operational, or Port Failure
— Segmented E_Port
Type—The type of port. Valid port types are a generic port (G_Port) not
connected to a Fibre Channel device, director, or switch (therefore light is not
transmitted); a fabric port (F_Port) connected to a device; or an expansion
port (E_Port) connected to a director or switch to form an interswitch link
(ISL).
Operating Speed—The operating speed of the port (Not Established, 1, or 2
Gb/sec.).
Alert—If Link Incident (LIN) alerts are configured for the port through the
Configure Ports dialog box, a yellow triangle displays in the column when a
link incident occurs. A yellow triangle also displays if beaconing is enabled
for the port. A red and yellow diamond displays if the port fails.
Open the Port Properties, Node Properties, or Port Technology dialog boxes.
Block or unblock the port.
Enable or disable port beaconing.
Perform port diagnostics.
Clear link incident alerts.
Reset the port.
Configure port binding.
Clear threshold alerts.
Repair Information