Event Codes
Table 99: Event Code 525 (Continued)
Event Data:
Byte 0 = port number (00 through 23).
Distribution:
Switch
EWS
Event
Log
Table 100: Event Code 581
Message:
Implicit incident.
Severity:
Major.
Explanation:
An attached open systems interconnection (OSI) server recognized a condition
caused by an event that occurred at the server. The event caused an implicit Fibre
Channel link incident.
Action:
A link incident record (LIR) is generated and sent to the attached server using the
reporting procedure defined in T11/99-017v0 (OSI). If fault isolation at the server
does not detect a failure, the problem may be due to a port failure. Go to
0000: Start
Event Data:
Refer to the T11/99-017v0 document for the specific link incident record format.
Distribution:
Switch
EWS
Event
Log
294
HAFM Appliance
System
Event
Error
Log
LED
MAP" on page 32 to perform fault isolation.