Table 46: Event Code 120
Message:
Error detected while processing system management command.
Severity:
Informational.
Explanation:
This event occurs when the switch receives an HAFM command that violates
specified boundary conditions, typically as a result of a network error. The switch
rejects the command, drops the switch-to-HAFM appliance Ethernet link, and forces
error recovery processing. When the link recovers, the command can be retried.
Action:
No action is required for an isolated event. If this event persists, perform a data
collection for this switch using the
procedure and return the backup disk to Hewlett-Packard support personnel.
Event Data:
No supplementary data included with the event.
Distribution:
Switch
EWS
Event
Log
Table 47: Event Code 121
Message:
Zone set activation failed–zone set too large.
Severity:
Informational.
Explanation:
This event occurs when the switch receives a zone set activation command that
exceeds the size supported by the switch. The switch rejects the command, drops
the switch-to-HAFM appliance Ethernet link, and forces error recovery processing.
When the link recovers, the command can be modified and retried.
Action:
Reduce the size of the zone set to conform to the limit specified, then retry the
activation command.
Event Data:
No supplementary data included with the event.
Distribution:
Switch
EWS
Event
Log
Edge Switch 2/24 Service Manual
HAFM
HAFM Appliance
System
Event
Error
Log
LED
HAFM Appliance
System
Event
Error
Log
LED
application. Perform the data collection
E-Mail
Call
Home
E-Mail
Call
Home
Event Codes
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident
263

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents