Event Codes
Table 48: Event Code 140
Message:
Congestion detected on an ISL.
Severity:
Informational.
Explanatio
Open Trunking firmware detected an ISL with Fibre Channel traffic that exceeded the
n:
configured congestion threshold.
Action:
No action is required for an isolated event. If this event persists, relieve the congestion
by adding parallel ISLs, increasing the ISL link speed, or moving device connections to
a less-congested region of the fabric.
Event Data:
Byte 0 = Port number reporting congestion.
Distribution
Switch
:
EWS
Event Log
Table 49: Event Code 141
Message:
Congestion relieved on an ISL.
Severity:
Informational.
Explanatio
Open Trunking firmware detected an ISL with Fibre Channel traffic that previously
n:
exceeded the configured congestion threshold. The congestion is now relieved.
Action:
No action required.
Event
Byte 0 = Port number reporting congestion relieved.
Data:
Distributio
Switch
n:
EWS
Event Log
264
HAFM Appliance
System
Event Log
Error LED
HAFM Appliance
System
Event Log
Error LED
E-Mail
Call-Home
E-Mail
Call-Home
Edge Switch 2/24 Service Manual
Host
Sense
Link
Info
Incident
Host
Sense
Link
Info
Incident

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents