HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual page 100

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

Diagnostics
4. Click Activate to save the configuration information and close the window.
Did reconfiguring the port type solve the problem?
NO
Contact the next level of support. Exit MAP.
24
One of the following mode-mismatch conditions was detected and an ISL
connection is not allowed:
Reconfigure the switch operating mode:
1. Ensure the switch is set offline. Refer to
2. At the Hardware View, click Configure > Operating Parameters > Fabric
102
Click expansion port (E_Port) if the port is cabled to a fabric element
(director or switch) to form an ISL.
YES
The switch appears operational. Exit MAP.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a fabric element not configured to Open Fabric 1.0 mode.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a legacy HP switch at the incorrect Exchange Link Parameter
(ELP) revision level.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch at the incorrect ELP revision level.
The switch is configured for operation in Open Fabric 1.0 mode and is
connected to a non-HP switch.
page 174.
Parameters. The Configure Fabric Parameters dialog box displays
(Figure
25).
"Set the Switch Online or
Edge Switch 2/24 Service Manual
Offline" on

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents