Map 0600: Port Failure And Link Incident Analysis - HP 316095-B21 - StorageWorks Edge Switch 2/24 Service Manual

Fw v06.xx/hafm sw v08.02.00 hp storageworks edge switch 2/24 service manual (aa-rtdxc-te, july 2004)
Hide thumbs Also See for 316095-B21 - StorageWorks Edge Switch 2/24:
Table of Contents

Advertisement

MAP 0600: Port Failure and Link Incident Analysis

This MAP describes fault isolation for shortwave laser small form factor
pluggable (SFP) optical transceivers, longwave laser SFP optical transceivers, and
Fibre Channel link incidents. Failure indicators include:
1
Was an event code 080, 081, 506, 507, 512, or 514 observed at the EWS Event
Log or at the Edge Switch Event Log (HAFM appliance)?
NO
2
Was an event code 581, 582, 583, 584, 585, or 586 observed at the console of an
OSI server attached to the switch reporting the problem?
YES
3
Table 12
that describe fault isolation procedures.
Edge Switch 2/24 Service Manual
An event code recorded at the EWS Event Log or Edge Switch Event Log
(HAFM appliance).
A link incident event code recorded at the console of an OSI server attached to
the switch reporting the problem.
One or more amber LEDs on the ports illuminate.
A port operational state message or a Failed message associated with a port
at the EWS interface.
One or more emulated amber LEDs on a port graphic at the Hardware View
illuminate.
A blinking red and yellow diamond (failed FRU indicator) appears over a port
graphic or a yellow triangle (attention indicator) appears at the alert panel of
the Hardware View.
A link incident message recorded in the Link Incident Log or Port Properties
dialog box.
YES
Go to
step
3.
NO
Go to
step
4.
lists event codes, brief explanations of the codes, and associated steps
Diagnostics
93