Diagnostics
Table 14: MAP 700 Event Codes (Continued)
Event Code
071
072
140
142
150
3
Is fault isolation being performed through the EWS interface?
YES
4
Does the EWS interface appear operational?
YES
5
Inspect the Fibre Channel port segmentation reason at the EWS interface.
1. At the View panel, click the Port Properties tab. The View panel (Port
2. Click the port number (0 through 23) of the segmented port.
3. Inspect the Reason field for the selected port.
Is the Reason field blank or does it display an N/A message?
NO
The Reason field displays a segmentation reason message.
reasons and associated steps that describe fault isolation procedures.
112
Switch is isolated.
E_Port connected to unsupported switch.
Congestion detected on an ISL.
Low BB_Credit detected on an ISL.
Zone merge failure.
NO
Fault isolation is being performed at the HAFM appliance. Go to
step
6.
NO
Analysis for an Ethernet link, AC power distribution, or CTP failure
is not described in this MAP. Go to
page 32. If this is the second time at this step, contact the next level of
support. Exit MAP.
Properties tab) displays.
YES
The switch ISL appears operational. Exit MAP.
Explanation
"MAP 0000: Start
Edge Switch 2/24 Service Manual
Action
Go to
step
14.
Go to
step
22.
Go to
step
23.
Go to
step
24.
Go to
step
25.
MAP" on
Table 17
lists the

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks edge switch 2/32

Table of Contents